Incubator-independent recirculation system vs peristaltic pump

Recirculation with microfluidics

Figure 1: Recirculation setup, 1: tight-closed loop, 2: open loop.

With microfluidics, it is possible to flow medium continuously over cells in culture. A microfluidic recirculation system involves fluid’s continuous and controlled circulation through microchannels in a closed-loop or open system. 

This system can be employed in spheroid cell culture, stem cell culture, organ-on-a-chip studies, for disease modeling and drug testing, since every cell of the human body is continuously irrigated via body fluids, whether in an open circuit (saliva, gastric fluid, urine…) or in a closed circuit (blood, lymph, pleural fluid…) (Figure 1).

In addition, a microfluidic recirculation system efficiently eliminates waste, saves the culture medium, and enriches the medium with cell secretion factors. However, loop recirculation requires the medium to be supplied with CO2 inside the chip. This can be done by using a gas-permeable material, a CO2-independent medium for short periods (about 2 hours), a CO2 incubator, or by implementing our incubator-independent recirculation setup.

Recirculation systems

At the Microfluidics Innovation Center, we have combined the cell culture pump, the recirculation loop, and the level sensors into one pack for an automated and stable incubator-independent recirculation.

This page starts with a general comparison of our incubator-independent recirculation system to recirculation with a peristaltic pump, then explains the story behind the development of our pack.

Comparison between recirculation with peristaltic pump vs our incubator-independent recirculation system

  Recirculation system with peristaltic pump Incubator-independent recirculation system
Common characteristics Unidirectional flow
Reduced reagent quantity
Volume-based
Different characteristics Might need a CO2 incubator No need for a CO2 incubator
Less stable and accurate flow control Highly stable and accurate flow control
Pulsatile flow Variety of flows: pulsatile, steady flow, stepwise….
Based on tube compression Based on gas pressure
Risk of recirculating cells damage No risk of recirculating cells damage
Tight-closed loop with 1 reservoir Open loop with 2 reservoirs and check valves
Input and output from the same reservoir Automatic switch between reservoirs

Recirculation with peristaltic pump

A recirculation system with a peristaltic pump provides a physiologically relevant cell microenvironment by sustaining a unidirectional flow through a microfluidic chip laden with cells. Compared to single-pass systems, it also reduces the amount of needed reagents. 

A peristaltic pump might need a CO2 incubator. It is a volumetric pump that compresses a flexible tube to transfer liquids, providing a pulsatile flow due to the cyclic nature of the peristaltic motion. Thus, the system can offer precise control but is less stable over time, requiring repeated flow rate calibration. Furthermore, due to the tube compression, there is a high risk of cell damage.

The system is volume-based and constitutes a tight-closed loop with only one reservoir serving as the input and output source (Figure 2).

setup-peristaltic-pump
Figure 2: Recirculation with peristaltic pump.

Incubator-independent recirculation system

Our incubator-independent recirculation system, which includes a cell culture pump and level sensors, offers the advantages of a pressure-driven flow controller plus the advantages of a peristaltic pump.

Similarly to recirculation with a peristaltic pump, our recirculation system allows a physiologically relevant cell microenvironment by sustaining a constant unidirectional flow and reduces reagent quantity. 

The cell culture pump is a pressure-driven flow controller that does not need a CO2 incubator. It offers a smooth, continuous, high-precision flow and the possibility of working with different flow profiles (pulsatile, steady, stepwise, etc.) based on the application. In addition, the pump is based on gas pressure with no risk of cell damage. 

Moreover, the system is volume-based but constitutes an open loop of two reservoirs that can serve as input and output sources. The level sensor senses the sample volume inside the reservoirs, and the system automatically switches to the second reservoir when the first reaches the level sensor threshold (Figures 3-4).

From reservoir 1 to reservoir 2:

recirculation with check valves and level sensors

From reservoir 2 to reservoir 1:

recirculation with check valves and level sensors 2

The story behind it

A closed circulation requires the medium to be supplied with CO2 inside the chip. Thus, a recirculation setup (with a pressure-driven flow controller or a peristaltic pump) using a gas-impermeable material and a CO2-dependent medium will need a CO2 incubator.

In addition, a recirculation system with a pressure-driven flow controller is time-based. It relies on the initial fluid volume and desired flow rates to estimate the time it takes for one reservoir to flow most of its volume through the sample and then manually switch to the other reservoir. In addition, this system cannot detect changes and adapt its functioning accordingly. If one of the reservoirs empties before expected due to biofouling or clogging, it introduces air into the system and damages the cells, ruining the experiment.

 

To overcome these downsides, we integrated cell culture pump and level sensors into the recirculation system. 

The cell culture pump maintains a stable and continuous nutrient supply at constant O2 and CO2 levels without needing a CO2 incubator (Figure 5). In addition, the cell culture pump does not exchange gas with the atmosphere as most pressure-driven controllers do. Pressuring the media reservoir with the correct gas mix prevents the gas in the media from diffusing into the atmospheric air. The constant media flow ensures that the correct composition always reaches the cells, even if the rest of the system is not gas-tight.

cell culture pump perfusion system
Figure 5: Cell culture pump.

The system, including level sensors (Figure 6), is volume-based; it will pressurize the first reservoir until it is nearly empty, then stop and start pressurizing the second reservoir. The researcher doesn’t have to wait for the first reservoir to reach the level sensor threshold to switch to the second one. Moreover, the level sensors introduce a fail-safe mechanism that considers the ever-evolving nature of a recirculation system, such as fouling of the tubing with dead cell debris, leakage due to clogging, and other blockage-related issues such as air entry.

level sensors perfusion system
Figure 6: Level sensors.

Funding and Support

The LIFESAVER project, funded by the European Union’s H2020-LC-GD-2020-3, grant agreement No. 101036702 (LIFESAVER), helped develop the level sensors. 

The Tumor-LN-oC project, funded by the European Union’s H2020-NMBP-TR-IND-2020 grant agreement No. 953234 (Tumor-LN-oC), helped develop the cell culture pump.

The ALTERNATIVE project, funded by the European Union’s H2020-LC-GD-2020-3 grant agreement No. 101037090, helped develop the check valve system.

The Galileo project, funded by the European Union’s Horizon research and innovation program under HORIZON-EIC-2022-TRANSITION-01 grant agreement No. 101113098 (GALILEO), helped develop the Galileo flow sensor. 

 

Tumor-LN-oC_Tumor-on-chip_ElvesysAlternative project logo biomedical researchlogo european commissionLogo LifesaverGALILEO logoimage

This review was written by Celeste Chidiac, PhD.

Published in July 2024.